SNFGE SNFGE
 
Thématique :
- Foie
Originalité :
Intermédiaire
Solidité :
Intermédiaire
Doit faire évoluer notre pratique :
Dans certains cas
 
 
Nom du veilleur :
Docteur Bertrand HANSLIK
Coup de coeur :
 
 
Gut
  2016/08  
 
  2016 Aug;65(8):1369-76  
  doi: 10.1136/gutjnl-2015-309260  
 
  The gamma-glutamyl transpeptidase to platelet ratio (GPR) predicts significant liver fibrosis and cirrhosis in patients with chronic HBV infection in West Africa.  
 
  Lemoine M, Shimakawa Y, Nayagam S, Khalil M, Suso P, Lloyd J, Goldin R, Njai HF, Ndow G, Taal M, Cooke G, D'Alessandro U, Vray M, Mbaye PS, Njie R, Mallet V, Thursz M  
  https://www.ncbi.nlm.nih.gov/pubmed/26109530  
 
 

BACKGROUND:

Simple and inexpensive non-invasive fibrosis tests are highly needed but have been poorly studied in sub-Saharan Africa.

METHODS:

Using liver histology as a gold standard, we developed a novel index using routine laboratory tests to predict significant fibrosis in patients with chronic HBV infection in The Gambia, West Africa. We prospectively assessed the diagnostic accuracy of the novel index, Fibroscan, aspartate transaminase-to-platelet ratio index (APRI), and Fib-4 in Gambian patients with CHB (training set) and also in French and Senegalese CHB cohorts (validation sets).

RESULTS:

Of 135 consecutive treatment-naïve patients with CHB who had liver biopsy, 39% had significant fibrosis (Metavir fibrosis stage ≥F2) and 15% had cirrhosis (F4). In multivariable analysis, gamma-glutamyl transpeptidase (GGT) and platelet count were independent predictors of significant fibrosis. Consequently, GGT-to-platelet ratio (GPR) was developed. In The Gambia, the area under the receiver operating characteristic curve (AUROC) of the GPR was significantly higher than that of APRI and Fib-4 to predict ≥F2, ≥F3 and F4. In Senegal, the AUROC of GPR was significantly better than Fib-4 and APRI for ≥F2 (0.73, 95% CI 0.59 to 0.86) and better than Fib-4 and Fibroscan for ≥F3 (0.93, 0.87 to 0.99). In France, the AUROC of GPR to diagnose ≥F2 (0.72, 95% CI 0.59 to 0.85) and F4 (0.87, 0.76 to 0.98) was equivalent to that of APRI and Fib-4.

CONCLUSIONS:

The GPR is a more accurate routine laboratory marker than APRI and Fib-4 to stage liver fibrosis in patients with CHB in West Africa. The GPR represents a simple and inexpensive alternative to liver biopsy and Fibroscan in sub-Saharan Africa.

 
Question posée
 
Valider en Afrique sub-Saharienne un marqueur non invasif de fibrose économique, le ratio gGT/plaquettes, chez les patients atteint d’hépatite B chronique.
 
Question posée
 
Ce marqueur est plus précis chez ces patients d’Afrique de l’ouest que l’APRI ou le Fib-4, pour détecter une fibrose significative ou sévère.
 
Commentaires

Très peu cher et performant, donc intéressant. Les performances de ce ratio sont identiques à APRI et Fib-4 dans la cohorte de validation française de cette étude.

 